What was found
AFTER ENGINE START, NR 1 ENGINE GENERATOR SHOWED NO VOLTS OR FREQUENCIES. WOULD NOT GO ON LINE. ACFT GROUNDED. NR 1 GCU LOGGED IDG FAULT. CLEARED FAULT & NR 1 GCU BITE, CHECKED NORMAL IAW FIM 24-21, TASK 801. SUBSEQUENT ENGINE RUN NR 1 IDG, OPS CHECKED NORMAL, IAW FIM 24-21, TASK 805. NO FAULTS LOGGED AFTER ENGINE SHUTDOWN.