What was found
START VALVE DID NOT OPEN ON THE NR 2 ENGINE. ACFT GROUNDED. PERFORMED FIM 80-07, TASK 803- LIGHT FOR NR 2 ENG START VALVE, OPS NORMAL. FOUND POSITION SWITCH FOR NR 2 ENG START VALVE INOPERATIVE. REPLACED START VALVE IAW MM 80-11-03-000-801-F00 AND 400-801-F00. OPS AND LEAK CHECKED NORMAL.