What was found
DURING LANDING CHECKLIST AND MASTER CAUTION RECALL, FWD CABIN ZONE TEMP LIGHT ILLUMINATED. WHEN MASTER CAUTION RESET IS PUSHED, LIGHT GOES OUT. ACFT GROUNDED. NR 2 CONTROLLER LOGGED ZONE TRIM VALVE IN BIT. NO FAULTS IN PREVIOUS FLIGHT. ACCOMPLISHED ZONE TEMP CONTROLLER BITE TEST REF MM 21-61-00, FAULT RESET, TEST PASSED.