What was found
NO LIGHT OFF ON NR 2 ENGINE DURING START PROCEDURE. ENGINE MOTORED FOR ONE MINUTE AFTER START LEVER MOVED TO CUTOFF. ACFT GROUNDED. REPLACED RT EXCITER IAW MM 74-11-01. OPS CHECKED GOOD FOR BOTH LT & RT IGNITORS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NO LIGHT OFF ON NR 2 ENGINE DURING START PROCEDURE. ENGINE MOTORED FOR ONE MINUTE AFTER START LEVER MOVED TO CUTOFF. ACFT GROUNDED. REPLACED RT EXCITER IAW MM 74-11-01. OPS CHECKED GOOD FOR BOTH LT & RT IGNITORS.