What was found
NR 2 START VALVE OPEN LIGHT REMAINED ILLUMINATED AFTER ENGINE START. ACFT GROUNDED. PERFORMED ENGINE NORMAL START PROCEDURE IAW 71-00-00. ALL OPS NORMAL, ACFT OK FOR SERVICE, IAW ENGINEERING REQUEST, REPLACED NR 2 START VALVE IAW AMM 80-11-03-000-801-F00. OPS CHECKED GOOD IAW AMM 71-00-00-800-811-FOO.