What was found
FWD CARGO DOOR CUTOUT FWD FRAME STRAP CRACKED AND DAMAGED ABOVE LIGHT SWITCH. ACFT GROUNDED. REMOVED EDGE DAMAGE FROM FAILSAFE STRAP AND FOUND WITHIN ALLOWABLE LIMITS IAW SRM 53-30-15-1A-1, FIG 103, DETAIL I. ORIGINAL STRAP WITH IS 1.5" WIDTH REMOVED IS 0.1 IN., ALODINED IAW SRM 51-20-01. PRIMED IAW SOPM 20-41-02. R & R PANEL 122BW PN 143A9403U186 IAW AMM 25-52-06 AND SRM 51-10-02 .