What was found
R2 DOOR WET AREA FLOOR WEB AT BS 986.5 AND RBL 29 IS CRACKED. ACFT GROUNDED. REMOVED AND INSTALLED THE WEB IAW SRM 51-40-02-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R2 DOOR WET AREA FLOOR WEB AT BS 986.5 AND RBL 29 IS CRACKED. ACFT GROUNDED. REMOVED AND INSTALLED THE WEB IAW SRM 51-40-02-0G-0.