What was found
APU BAY RT BULKHEAD AFT CUTOUT FWD LANDING HAS A CORRODED SPOT ON THE BACKSIDE. ACFT GROUNDED. AT APU COMPARTMENT RT BULKHEAD AFT CUTOUT, FWD STIFFENER REMOVED CORRODED OUT OF LIMITS, R & R DAMAGED STIFFENER IAW SRM 53-80-13-1A-2, FIG 101, 51 40-02-0G-0, W 2.00, O .063, R .022, L 2.00, D .041.