What was found
AFT CARGO BAY RT SIDEPLATE CHANNEL HAS OVERSIZED HOLES FROM FASTENERS PULLING THROUGH AT STA 727F, 727G, AND 727H. ACFT GROUNDED. REMOVED DAMAGE AREA IAW SRM 53-00-53-2R. FABRICATED NEW SIDEPLATE SECTION AND SIDEPLATE SPLICE IAW SRM 53-00-53-2R. ALODINED REPAIR PARTS IAW SRM 51-20-01. PRIMED REPAIR PARTS IAW SOPM 20-41-02 INSTALLED NUT PLATES AND REPAIR PARTS IAW SRM 53-00-53-2R-5. REMOVED AND REINSTALLED FLOOR PANEL 140EF FOR ACCESS IAW AMM 25-52-10.