As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CONTROL CABIN ZONE TEMP LIGHT CAME ON WHEN RECALL PUSHED. LIGHT WENT OUT WHEN MASTER CAUTION RESET WAS PUSHED. ACFT GROUNDED. PERFORMED NR 2 CONTROLLER BITE 21-62, TASK 801. FOUND MESSAGE FLT DECK TRIM VALVE FAULT. RESET FAULT. GROUND RAN RT PACK FOR 1 HOUR. PERFORMED BITE AGAIN , NO FAULTS LOGGED. SYS CKS NORMAL.