What was found
AFT WET AREA BS 986.5 AT RBL 30 AND 45 HAS SURFACE CORROSION ON TOP OF FLOORBEAM. ACFT GROUNDED. BLENDED DAMAGED AREA IAW SRM 51-10-02-0G-0 MATERIAL REMAINING IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-60-51-1A-1, REPAIRED DAMAGED AREA IAW EA 400-53EA-13928, REV NEW DATED 12DEC14 ORIGINAL MATERIAL THICKNESS .150 MATERIAL, REMAINING IS .108.