What was found
PRESSURIZATION AUTO FAIL ON TAXI AUTO FAIL LIGHT AND GREEN ALTN LIGHT ILLUMINATED. ACFT GROUNDED. PERFORMED AUTO FAIL LIGHT ON FAULT ISOLATION IAW FIM TASK 21-31, TASK 827. FOUND SEL PANEL LRU FAIL ON NR 2 DCPC BITE. PERFORMED CPC MODULE DISPLY FAULT ISOLATION IAW FIM 21-31, TASK 803. FAULT CLEARED, NO EXISTING FAULTS DISPLAYED, NO ADDITIONAL MAINTENANCE REQUIRED REF FIM 21-31, TASK 803 (E)(3)(C).