What was found
R1 DOOR CUTOUT THRESHOLD SUPPORT HAS MULTIPLE CORROSION SPOTS. ACFT GROUNDED. R & R THRESHOLD SUPPORT IAW SRM 51-40-02-0G-0, W 1, O .090, R .073, L 2", D .017.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R1 DOOR CUTOUT THRESHOLD SUPPORT HAS MULTIPLE CORROSION SPOTS. ACFT GROUNDED. R & R THRESHOLD SUPPORT IAW SRM 51-40-02-0G-0, W 1, O .090, R .073, L 2", D .017.