What was found
FWD CARGO BAY, AFT LT BULKHEAD TO FLOOR SUPPORT ATTACH ANGLE IS CORRODED. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2. R & R THE ATTACH ANGLE IAW AMM 25-52-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BAY, AFT LT BULKHEAD TO FLOOR SUPPORT ATTACH ANGLE IS CORRODED. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2. R & R THE ATTACH ANGLE IAW AMM 25-52-06.