What was found
FIRE DETECTON SYS FAILED TEST, NR 2 ENGINE LIGHT FAILED TO ILLUMINATE. ACFT GROUNDED. UNABLE TO DUPLICATE DEFECT. NR 2 ENGINE, LOOP B TESTS NORMAL AND M279 CONTROL MODULE SHOWS NO FAULTS WITH LOOP SELECT SWITCH SET TO "BOTH". OPENED COWLS AND INSPECTED NR 2 ENGINE FIRE DETECTION LOOPS AND WIRE HARNESS CONNECTIONS TO LOOPS, NO DEFECTS NOTED. REMOVED, CLEANED, AND REINSTALLED WIRE HARNESS CONNECTIONS FOR LOWER FAN DETECTOR LOOP. CLOSED COWLS AND PERFORMED FIRE AND OVERHEAT DETECTION SYS. OPS TEST IAW MM 26-10-00-710-801. ALL TESTS PASSED.