What was found
WHILE ACCOMPLISHING T/C 78472040, FOUND UNIDENTIFIABLE NON-MAGNETIC PARTICLES LARGER THAN .4" IN FWD SUMP SCAVENGE SCREEN MCD ON NR 2 ENGINE. MM 79-00-00-210-010, STEP 8 NEEDS TO BE ACCOMPLISHED. ACFT GROUNDED. ACCOMPLISHED STEP H8-10. NO ADDITIONAL NR 2 ENGINE FWD SUMP FINDINGS NOTED. SUBJECT DEBRIS SENT FOR LABORATORY ANALYSIS. ENGINE MAY CONTINUE IN SERVICE PENDING RESULTS REF MM 79-00-00-200-804-F00. CURRENTLY ON REDUCED INTERVAL INSPECTION.