What was found
FLOORBEAM, LBL 45 FLANGE CORRODED AT STA 578-601. ACFT GROUNDED. R & R FLOORBEAM, LBL 45, UPPER CAP IAW SRM 51-40-02-0G-0, W 4", O .090", R .077", L 150", D .013.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM, LBL 45 FLANGE CORRODED AT STA 578-601. ACFT GROUNDED. R & R FLOORBEAM, LBL 45, UPPER CAP IAW SRM 51-40-02-0G-0, W 4", O .090", R .077", L 150", D .013.