As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO DOOR SURROUND, LOWER MAIN SILL CENTER STRAP IS DENTED AT APPROXIMATELY BS 470. ACFT GROUNDED. R & R STRAP IAW BAC DWG 143A8120 AND SRM 51-40-02 AND SRM 51-10-02, PARA 9. REMOVED DOT L376, REMOVED AND REINSTALLED FLOOR PANELS 120AF AND 120CF IAW AMM 25-51-10.