What was found
RAMP REPORTED A GOUGE AT FWD CARGO FLOOR. ACFT GROUNDED. REMOVED FWD CARGO SCUFF PLATES IAW AMM 53-11-02. REMOVED LOWER SILL WEB AND INSTALLED NEW WEB IAW SRM 51-10-02 PARA 9, SRM 51-40-02, AND BAC DWG 143A8330, REV A. ACCOMPLISHED PERMANENT WELD REPAIR TO SCUFF PLATE THRESHOLD PANEL IAW EA 5320-01456, REV D. INSTALLED FWD CARGO SCUFF PLATES IAW AMM 53-11-02. IN REFERENCE TO DISCREPANCY AS WRITTEN, DAMAGE LOCATION IS DESCRIBED AS SCUFF PLATE, NOT FLOOR, IAW SRM.