What was found
DEBRIS FOUND IN NR 2 ENGINE IDG SIGHT GLASS. ACFT GROUNDED. REMOVED NR 2 ENGINE IDG SIGHT GLASS , FOUND DEBRIS TO BE DISLODGED DEPOSITS CONTAINED WITHIN SIGHT GLASS CAVITY. CLEANED CAVITY OF REMAINING DEPOSITS, REINSTALLED SIGHT GLASS IAW CMM 24-11-85 P.715. EXAMINED IDG FILTERS, NO CONTAMINATION FOUND. OPS & LEAK CHECK OF NR 2 ENGINE IDG GOOD. GROUND VERIFICATION SUCCESSFUL IAW MM 24-11-00-700, STEP 3. A.-F.