LEFT PACK LIGHT ILLUMINATED WITH RECALL EXTINGUISHES ON RESET. ACFT GROUNDED. INSPECTED FAN BYPASS CHECK VALVE ON LT PACK PRIMARY PLENUM/DIFUSER ASSY FOR OPERATION AND SECURITY. BYPASS CHECK VALVE CHECK IS NORMAL. ACCOMPLISHED BITE PROCEDURE OF NR 1 PACK/ZONE TEMP CONTROLLER. FAULTS LT PACK TEMP CONTROL VALVE. R & R LT PACK TEMP CONTROL VALVE IAW AMM 21-51-10. OPS CHECK AND BITE VERIFY OK. STARTED BOTH ENGINES AND CONFIGURED FOR OPERATION. NO FAULTS ON RECALL NOTED.