What was found
FORWARD CARGO BAY BS 500L LT AT TRANSITION STRIP CORRODED. ACFT GROUNDED. REMOVED CORROSION AT STA 500K TO 500K+ TO 500KH2 REMAINING .0.38". FOUND TO BE WITH IN LIMITS IAW SRM 53-00-53-14-2. REMOVED CORROSION AT STA 500KH3 TO 500K+19. ORIG THICKNESS .040" LOSS 0.009" REMAINING 0.03" TO 500K"19 ORIG THICKNESS 0.04"LOSS 0.009" REMAINING REMAINING 0.03" FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 REPAIRED AREA IAW SRM 53-00-53-2R-5 ALODINED AND PRIMED IAW SRM 51-20-01. PAINTED IAW SRM 51-20-01.