What was found
L1 DOORWAY UNDER SCUFF PLATE INBD SUPPORT ANGLE SEVERAL SPOTS CORROSION BS 312-BS 348. ACFT GROUNDED. BLENDED CORROSION AT L1 DOOR LOWER SILL INBD SUPPORT ANGLE, FOUND TO BE IN LIMITS IAW SRM 53-10-15, ALODINED & PRIMED IAW SRM 51-20-01, MARKED BLENDED AREAS IAW AMM 51-05-01. ORG MAT THICKNESS .080, REMOVED .002, .078 REMIANS BLEND OUTS (A) 3.4 X .800 (B) 3.5 X .850 (C) 1.2 X .450.