What was found
L2 DOOR CUTOUT IS CRACKED AT FWD LOWER CORNER IN BEARSTRAP MARKED IN RED. ACFT GROUNDED. REPAIRED L2 DOOR CUTOUT FWD LOWER CORNER IAW SRM 53-00-01-2R-32, REPAIR 32, THIS REPAIR IS A CATEGORY B REPAIR, REQUIRES INSPECTION WITH THRESHOLD OF 66,000 AND INTERVAL OF 24,000 FLT CYCLES. CURRENT ACFT CYCLES IS 37,704. NOTE: CAT B INFORMATION BEING TRACKED IN FILEMAKER PRO. RTOWELL 74711.