Service difficulty report · Valve · Boeing 737990ER

Difficulty date
April 25, 2015
Submitted
April 29, 2015
Operation
Air carrier
Aircraft
N440AS
Make and model
Boeing 737990ER
Aircraft serial
41705
Aircraft time
5,760 hours, 1,886 cycles
Part
Valve
Part number
3989084
Part serial
18279
Condition
Malfunctioned
Location
A/C Bay
Part time
8,025 hours, 2,665 cycles
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED UPON DEPARTURE-LIGHT WENT OUT WHEN MASTER CAUTION WAS RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST IAW MM 21-61-00-700-806-002. NR 2 TEMP CONTROLLER LOGGED FLT DECK TRIM VALVE. REPLACED FLT DECK TRIM VALVE IAW MM 21-61-21. VALVE OPS CHECKS, LEAK CHECKS GOOD. NO FAULTS LOGGED ON NR 2 TEMP CONT.