What was found
FORWARD PIT, LT SIDE TRANSITION FLOOR PANEL HAS CORROSION AT VARIOUS SPOTS. BS 500C-BS 500I, STR 26L. ACFT GROUNDED. BLENDED AREA OF CORROSION ON LT TRANSITION PANEL AND CHECKED LIMITS IAW SRM 53-53-1A-2. REMOVED TRANSITION PANEL SECTION BS 500G+10 TO BS 500I WHICH WAS FOUND TO BE OUT OF LIMITS AIW SRM 51-40-02, TRANSITION PANEL AT SECTION BS 500C TO BS 500G+10. FOUND TO BE WITHIN LIMITS AIW SRM 53-00-53-1A-2. APPLIED ALODINE, PRIMED, PAINT, AND CIC IAW SRM 53-00-53-1A-2. RECEIVED NEW PANEL MATERIAL , BAC 1496-444, 2EA, CHANNEL 7075T6 PO 837830.6 AND FABRICATED NEW REPAIR SPLICE PLATE AND TRANSITION PANEL SECTION IAW SRM 53-00-53-2R-5, REPAIR S. ALODINED AND PRIMED NEW TRANSITION PANEL AND SPLICE PLATE IAW SRM 53-00-53 -2R-S, REPAIRS INSTALLED, NEW PANEL & SPLICE PLATE IAW SRM 53-00-53-2R-S. REPAIRS AND SRM 51-40-02, REMOVED DOT.