What was found
RT INBD FLAP, EB RIB TORQUE TUBE FITTING HAS PITTING , DISCOVERED AFTER REMOVING TORQUE TUBE. ACFT GROUNDED. REMOVED DAMAGE, FOUND TO BE ACCEPTABLE FOR CONTINUED SERVICE IAW SAS EA 400, 57EA, 15179, REV. NEW DATED 04JUN15. THIS IS A CATEGORY B REPAIR STAGE 1 REF, CMPT 57DTI, 15180, W 1", O .250, R .247, L .003, D 3".