What was found
AFT PIT RT TRANSITION PANEL, UPPER & LOWER SURFACE SKIN CORRODED AT SEVERAL SPOTS. DOTTED. BS 767 - BS 792, RBL 25 - 35, STR 26R. ACFT GROUNDED. REMOVED DAMAGE FROM AFT PIT RT LWR MAIN SILL-SHIELD IAW SRM 53-00-53-1A-2 4.A.2. ORIGIONAL THICKNESS IS .050 IAW DWG 146A8127, REV: C. REMOVED .007 REMAINING THICKNESS IS .043, AND IS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 4.A. REMOVED SHIELD IAW SRM 51-40-02. LOCATED AND DRILLED UP NEW SHIELD IAW DWG 146A8127 REV. INSTALLED NEW SHIELD IAW DWG 146A8127, REV.