What was found
AFT CARGO FLOOR PANEL JOINT STRIP, UPPER SURFACE HAS CORROSION AT SEVERAL SPOTS. BS 887, LBL 25 - RBL 25, STR 26L-STR 26R. ACFT GROUNDED. RECIEVED NEW TEE ASSY 146A9401V39, LOCATED, DRILLED AND INSTALLED NUTPLATES IAW BAC DWG 146A9401 REV "A" AND SRM 51-40-05, R & R IAW AMM 25-52-10, PO 839853.1, DOT REMOVED.