What was found
AFT CARGO COMPARTMENT, FWD DOOR SURROUND SHIELD IS CORRODED, APPROXIMATELY BS 767-BS 787. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-60-15-1A-1, ORIGINAL THICKNESS IS .050 IN REMAINING THICKNESS IS .039 IN REMOVED .011 IN, BEYOND MAX ALLOWABLE 10 PERCENT, R & R SHIELD IAW SRM 51-10-02, PARA 9, SRM 51-40-02 AND ABC DWG 146A0081 SHT 34 REV-.