What was found
FWD CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXT ON MAST CAUTION RESET. ACFT GROUNDED. VERIFIED ZONE TRIM FAULT ON THE NR 2 ZONE TEMP CONTROLLER. REPLACED THE FORWARD CABIN ZONE TRIM MODULATING VALVE IAW AMM'S 21-61-21-000-801 AND 21-61-21-400-801. VALVE OP CHECKED GOOD.