What was found
MAIN CABIN FLOORBEAM CRACKED BS 540, BL 0 - RBL 5. ACFT GROUNDED. REMOVED THE CRACKED FLOORBEAM IAW SRM 51-40-02, PARA NR 7. DRILLED TO FIT NEW FLOORBEAM IAW SRM 51-40-05. INSTALLED THE NEW FLOORBEAM IAW SRM 51-40-02, PARA NR 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOORBEAM CRACKED BS 540, BL 0 - RBL 5. ACFT GROUNDED. REMOVED THE CRACKED FLOORBEAM IAW SRM 51-40-02, PARA NR 7. DRILLED TO FIT NEW FLOORBEAM IAW SRM 51-40-05. INSTALLED THE NEW FLOORBEAM IAW SRM 51-40-02, PARA NR 7.