What was found
FWD PIT LT TRANSITION PANEL CORRODED BS 500F TO 500I. ACFT GROUNDED. ACCOMPLISHED BLENDOUT OF CORRODED AREA IAW SRM 51-10-02. ORIG MATERIAL: .040" REMOVED MATERIAL: 035 MATERIAL LOSS: .005". DAMAGE WAS FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2, DET C. R & R FWD PIT LT TRANSITION PANEL FROMS TA 500D +10 TO BS 500I, APPLIED ALODINED TO REPAIR PARTS IAW SRM 51-20-01 AND SRM 53-00-53-1A-2, REPAIR 5. APPLIED PRIMER TO REPAIR PARTS IAW SOPM 20-41-02 DOT REMOVED.