Service difficulty report · Valve · Boeing 737990ER

Difficulty date
July 1, 2015
Submitted
July 7, 2015
Operation
Air carrier
Aircraft
N431AS
Make and model
Boeing 737990ER
Aircraft serial
43255
Aircraft time
6,730 hours, 2,211 cycles
Part
Valve
Part number
3989083
Part serial
9165
Condition
Malfunctioned
Location
Rt A/C Pack
Part time
27,393 hours, 9,603 cycles
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MASTER CAUTION AND RT PACK LIGHT ILLUMINATED ON SHORT FINAL. ACFT GROUNDED. REPLACED CONNECTOR, D3872 IAW WDM 21-52-22 AND TEMPERATURE CONTROL VALVE, PRECAUTIONARY, IAW MM 21-51-10-000-801/21-51-10-400-801. PERFORMED TEMP CONTROL VALVE INSTALLATION TEST IAW MM 21-51-10-400-801, PARA E. INSTALLATION TEST IS GOOD. PERFORMED PACK TEMP CONTROL BITE TEST IAW FIM 21-62, TASK 801, NO FAULTS NOTED.