What was found
AFT CARGO FLOOR PANEL SPLICE TEE AT BS 727F+5 IS CORRODED/EXFOLIATED, PARTS RACK. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-60-53-1A-1, DETAIL IV SECTION B-13. ORIGINAL THICKNESS 0.070, REMOVED 0.015, REMAINING THICKNESS 0.055, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53-1A-1, TOOL, T8225P, REPLACED SPLICE TEE IAW IAW SRM 51-10-02 PARA AND IAW BAC DWG 65C82630, REV: B, LOCATED AND DRILLED AND INSTALLED NUT PLATES TO NEW SPLICE IAW BAC DWG 65C32630, REV: B REMOVED DOT B632. REMOVED DISCREPENT SPLICE AND INSTALLED NEW SPLICE IAW SRM 51-40-02. .