What was found
AFT CARGO COMPARTMENT, DOORWAY FLOOR SUPPORT TRACK IS CORRODED/EXFOLIATED. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-60-53-1A-1. ORIGINAL MATERIAL THICKNESS WAS 0.090", REMOVED 0.052", REMAINING THICKNESS WAS 0.038". ACCOMPLISHED PARTIAL TRACK REPLACEMENT IAW SRM 53-00-53-2R-2 FROM APPROXIMATELY BS 757-STA 877, RBL 13.8.