What was found
LOW PRESSURE FOR CENTER FUEL PUMP ILLUMINATED WITH APPROXIMATELY 12,000 LBS FUEL IN CENTER TANK. FOLLOWED QRH PROCEDURE, OPEN CROSSFEED, RT CENTER PUMP OFF AND LIGHT EXTINGUISHED. CENTER TANK FUEL BURN CONTINUED NORMALLY. ACFT GROUNDED. R & R RT CENTER FUEL PUMP IAW AMM 28-22-41-000-801 & 400-801. PERFORMED BOUNDING CHECK, CHECKED GOOD IAW SAME MM 28-22-41. PERFORMED OPS TEST OF RT CENTER TANK BOOST PUMP IAW AMM 28-22-41-710-801. NO LEAKS NOTED BOOST PUMP OPERATES AS REQUIRED.