What was found
BS 500F STRINGERS 20 - 21L FRAME IN FWD CARGO BAY, A .500 HOLE HAS CRACK INDICATION NOTED IN FRAME AT 5 O'CLOCK POSITION. ACFT GROUNDED. REPAIRED THE FRAME IAW SRM 53-00-07-2R-13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 500F STRINGERS 20 - 21L FRAME IN FWD CARGO BAY, A .500 HOLE HAS CRACK INDICATION NOTED IN FRAME AT 5 O'CLOCK POSITION. ACFT GROUNDED. REPAIRED THE FRAME IAW SRM 53-00-07-2R-13.