What was found
ENGINE 1 ALTN POWER CHANNEL A CIRCUIT BREAKER FOUND POPPED ON PREFLIGHT. ACFT GROUNDED. CHECKED C/B PANEL, RESET C/B, PREFORMED FIM 73-00, TASK 801, NO FURTHER PROBLEMS, OPS GOOD, REF MM 20-60-01. PERFORMED GROUND VERIFICATION TEST IAW MM 73-21-00-700-804-F00 ON ENGINE NR 1 ELECTRONIC ENGINE CONTROL. TESTS PASSED.