AFT CARGO SIDEWALL CAPSTRIP SPLICE IS CORRODED. ACFT GROUNDED. REMOVED CORROSION MEASURED THICKNESS OF METAL, ORIGINAL THICKNESS .063, REMOVED .031, REMAINING THICKNESS .032 FOUND TO BE PAST 10 PERCENT ALLOWABLE LIMITS IAW SRM 53-60-53. REPLACED IAW SRM 53-60-53. REPLACED IAW SRM 51-10-02, PARA 8 LOCATED AND DRILLED HOLES IAW DWG 6532630, REV B AND 6532631 REV A.