What was found
AFT CARGO SIDEWALL CAPSTRIP IS CORROSION LT NR 1. ACFT GROUNDED. REMOVED CORROSION MEASURED THICKNESS OF METAL. ORIGINAL THICKNESS .063, REMOVED .022, REMAINING THICKNESS .041 FOUND TO BE PAST 10 PERCENT ALLOWABLE LIMITS IAW SRM 53-60-53. REPLACED IAW SRM 51-10-02, PARA 8. LOCATED AND DRILLED HOLES IAW DWG 65C32630, REV B & 65C32630, REV B 65C32631, REV A.