What was found
PARTS RACK, AFT CARGO FLOOR/SIDEWALL CAPSTRIP IS CORRODED, RT NR 3. ACFT GROUNDED. REMOVED CORROSION FROM PANEL, ORIGINAL THICKNESS .063. REMAINING THICKNESS .039 FOUND TO BE OUT OF LIMITS WITH MINIMUM THICKNESS REMAINING OF .057 IAW SRM 53-60-53, 10 PERCENT. REMOVED -.024 TOOL, T8225Y, CAL 11-25-15 MATERIAL ID T2024T3, PO 837825.1 IAW DWG 65C32630, REV B, FABRICATED NEW CAP STRIP IAW BAC DWG 65C32650, REV B ALODINED AND PRIMED IAW SRM 51-20-01, PAINTED IAW AMM 51-21-73, REMOVED DOT B9960.