What was found
RIGHT BS 500B, .500" WIRE PENETRATION HOLE, ABOVE S-21R HAS CRACK INDICATION DUE TO NOISE. IN FWD PIT, MARKED. ACFT GROUNDED. CLEANED HOLE RT BS 500B, 500" WIRE PREPERATION, HOLE ABOVE S-21R IAW NDT MANUAL PART 6, 51-00-00 PROCEDURE 1, PARA 4, CRACK INDICATION STILL NOTED, ACCOMPLISHED REPAIR TO FRAME AT BS 500B, S20R TO S21R IAW EA 400-53EA-15608, REV NEW.