What was found
AFT CARGO COMPARTMENT, RT CAPSTRIP NR 3, FWD OF DOORWAY IS CORRODED. ACFT GROUNDED. REMOVED CORROSION MEASURED THICKNESS OF METAL USING TOOL T82254 CAL DATE 11/25/2015, ORIGINAL THICKNESS .063", REMOVED .024" REMAINING THICKNESS .039" FOUND TO BE OUT OF ALLOWABLE LIMITS, NEW PART ORDER 65-4931.-25, PO 844404.1, LOCATED AND DRILLED HOLES IN NEW PART IAW DWG 65C32630, REV B 65C32631, REV A, CAP STRIP WILL BE REINSTALLED ON CUSTOMER CARD G542070. ALLOWABLE LIMITS IAW SRM 53-60-53.