What was found
AFT CARGO COMPARTMENT, RT CAP STRIP NR 4, AFT OF DOORWAY IS CORRODED. ACFT GROUNDED. REMOVED CORROSION, MEASURED THICKNESS OF METAL, ORIGINAL THICKNESS -.063. REMOVED -.012 REMAINING THICKNESS .051 FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53, MAT ID 2024-T3, PO 837825.1 IAW DWG 65C32630, REV: B, FABRICATED NEW CAP STRIP IAW DWG 65C32630, REV: B, ALODINED AND PRIMED IAW SRM 51-20-01, PAINTED IAW AMM 51-21-73.