What was found
AFT PIT TRANSITION PANEL CORRODED BS 727E-BS 787, LBL 24. ACFT GROUNDED. REMOVED CORROSION ON TRANSITION PANEL AT BS 527E-BS 787, LBL 24 ORIGINAL THICKNESS .040, REMOVED .006,034, REMAINING FOUND TO BE OUT OF LIMITS IAW SRM 53-00-543-1A-2,4A TOOL T82252, REMOVED TRANSITION PANEL FROM BS 727E-807, LBL 24, FABRICATED NEW SECTION AND INSTALLED IAW SRM 53-00-43-2R-5 DOT REMOVED PO 843790.6.