What was found
NR 2 ENGINE FAILED TO START. ACFT GROUNDED. R & R NR 2 ENGINE SPAR VALVE ACTUATOR IAW MM 28-21-11. OPS CHECKED GOOD. PERFORMED ENGINE RUN AS REQUIRED IAW GPM 05-00-06. ENGINE NR 2 RUNS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 ENGINE FAILED TO START. ACFT GROUNDED. R & R NR 2 ENGINE SPAR VALVE ACTUATOR IAW MM 28-21-11. OPS CHECKED GOOD. PERFORMED ENGINE RUN AS REQUIRED IAW GPM 05-00-06. ENGINE NR 2 RUNS NORMAL.