What was found
L2 DOOR CUTOUT FWD LWR CORNER FUSE SKIN IS CRACKED. ACFT GROUNDED. REPAIRED FUSELAGE SKIN IAW SRM 53-00-01-2R-32, DETAIL IV THIS IS A CATEGORY B REPAIR INITIAL THRESHOLD IS SET AT 66,000 CYCLES INTERVALS SET AT 24,000 CYCLES, SRM 53-00-01-212-32, TABLE IX FOR INSPECTION METHODS.