What was found
RIGHT FUEL QTY GAUGE INOPERATIVE DURING POWER TRANSFER. ACFT GROUNDED. ACCOMPLISHED FQIS BITE REF FIM 28-41, TASK 801. FAULT MESSAGE RECEIVED: 28-41215, TANK 2 OUTPUT BUS FAILED. R & R FUEL QUANTITY PROCESSOR UNIT REF AMM 28-41-81. OPS TEST NORMAL.