What was found
AFT PIT FRAME BS 827 FAILSAFE ANGLE IS CORRODED BS 25L TO 23L. ACFT GROUNDED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07-A-1 DETAIL II. R & R FAILSAFE ANGLE IAW SRM 51-40-02-0G-0, W 1", O .045", R .038:", L 2.00", D .007".